EMMA PROBLEMS FIXED AS OF 02/22/07

Fixed in Release: 5.0.23a  Problem:  When trying to edit AuxForm "Receipt of Patient" - getting Run Time Error.
Response:  Fixed code in Display Frame.

Problem:  
When running Microsoft Vista, EMMA gets an error message at startup.
Response:  Workaround: ignore message. Fixed in 5.0.23.

Reqest:
 Need to be able to document usage of EZ-IO Gun.
Response:  Added to IOIVCatheter Table in axtables.mdb. Two entries for Catheter Size: EZ-IO Adult and EZ-IO Pediatric.

Request:  
JCAHO has banned certain abbreviations ANYWHERE in the patient record.  The only problems that I found in my charts concerned the use of decimal point/ zeros.  WE can't use a zero after a decimal point and we must use a zero before a decimal.  On any ETT placement the default on the dropdown uses a following zero (8.0 etc) that cannot be there.  The only med dose problem that I found was for NTG the default dropdown is .4 mg and we have to use 0.4 mg.  Any way to change these?
Response:  
You can change the default dose for NTG in the axtables.mdb database in the Medications table.  Change the field DefaultDose for MedSeqNum = 23 (Nitroglycerine).

To Suppress a trailing zero in the ETT entry of the TreatmentLog, insert the line SUPPRESSTRAILINGZERO=1 in the [Narrative] section of the emma.ini file.  A value of 0 (the default) will keep the Trailing Zero.

Problem:  When adding a new user, the UserLevel and other fields are not being displayed when the user is authorized to a service.
Response:  Fixed code in AuthorizeUserBtn so if only one service is authorized, that service is automatically selected.

Request:  Need to have Resp Mode to Scene and Trans Mode From Scene appear in top of PCR.
Response:  Added Resp Mode and Trans Mode to PCR.

Request:  Need a report to show 12-Lead treatments.
Response:  Added report tp031in.rpt in Reports-->QA.

Problem:  The report Trip List by Incident Number by Neighborhood (tp024nb.rpt) gets an error while attempting to run.
Response:  Fixed error in Reports.mdb file.

Problem:  When trying to enter a new user, getting error 402 - must close or hide topmost modal form first.
Response:  Happens when machine is setup to use WAN but WAN is not reacable on the network.  Solution is to connect to the WAN or to comment out WANSERVERLOC in EMMA.INI file.

Problem:  In export to AIM billing (RAM), the tripdate is set to the date the trip was entered rather than the Date Dispatched.
Response:  Changed code in CollectRamTripInfo to use the DateDispatched.